Use and regulation of transducer for triangular bag tea packing machine
After the transducer is connected to the power supply before A. is used, the frequency tracking mode must be adjusted to ensure that the frequency deviation indication and the load indication are all "0". Otherwise, the frequency shift will cause the transducer to burn out (the new machine does not need this).
The connection surface between B. transducer and welding head must be clean. If there is foreign matter, please wipe it with acetone or absolute alcohol. The transducer must be screwed up with the welding head.
C. must ensure that the transducer has a good cooling environment. The transducer temperature must be below 60 degrees Celsius, otherwise it will burn out the transducer.
D. strictly prohibit changing the dimensions of the transducer and the welding head. Otherwise, the transducer and the welding head should be removed. The maximum correction for the front end wear of the welding head should be less than 0.5mm..
|